language EN
precision_manufacturing Architectural Systems Manufacturing Hub

Engineered Architectural Metal & Facade Cladding Systems

Precision-manufactured aluminum alloys and cold-rolled steel building envelopes tailored for international curtain wall contractors, facade consultants, and commercial mega-projects. Engineered to withstand peak cyclonic wind pressures and stringent international fire safety mandates.

unfold_more
unfold_more
unfold_more
unfold_more
Structural Facade Portfolio

Architectural Metal Catalog

Showing 0 of 0 Systems
inventory_2

No product systems are published yet. Please check back soon or contact our engineering team for the latest catalog.

Engineering Selection Matrix

Material Performance & Engineering Benchmark

Compare structural parameters, fire ratings, mass, and span capabilities across our primary manufactured architectural facade systems to select the optimal envelope solution.

verified Verified under GB/T 15227, ASTM E330 & EN 13830 standards
System Architecture & Caliber Substrate / Core Specification Fire Safety Standard Areal Mass Structural Span & Rigidity Max Panel Span Ideal Architectural Application
Solid Aluminum Cladding 2.5mm / 3.0mm Monolithic AA3003-H14 / AA5052-H32 (Customized per Project) Class A1 / A2 EN 13501-1 / ASTM E84 6.8 – 8.1 kg/m² Welded stiffeners @500mm; wind loads to 5.2 kPa 2,200 × 6,000 mm Complex 3D organic hyperboloids, transit terminals, high-impact podiums
Aluminum Honeycomb Panel 15mm – 25mm Composite AA3003-H24 (0.4–1.5mm Skins) + Anodized Hex Core (Foil 0.04–0.06mm, Cell 4–6mm) Class A1 / A2 GB 8624 / EN 13501-1 5.5 – 6.8 kg/m² EI ≥ 450 N·m²; unassisted span 2,400mm (Zero oil-canning) 2,300 × 12,000 mm Super-tall curtain walls, airport concourses, massive flat soffits with zero oil-canning
Corrugated Core ACCP 4.0mm All-Aluminum Core AL3003 H16-H18 (0.5–1.0mm Face) + 0.15–0.3mm Wave Core Class A1 / A2 100% Recyclable Metal 4.5 – 5.0 kg/m² High rib modulus; span 1,500mm unassisted 1,500 × 6,000 mm High-rise curtain wall spandrels, cost-engineered facades, fast-track retrofits
Architectural Steel Wall Panel 12mm – 16mm Modular System Hot-Dip Galvanized Steel (0.6–1.0mm) + Calcium Silicate / Gypsum / Honeycomb Class A1 / A2 GB 8624 / EN 13501-1 12.5 – 16.0 kg/m² High surface hardness, scratch/impact resistant; tongue-and-groove dry lock 1,200 × 3,600 mm Hospitals, operating theaters, cleanrooms, subway stations, public service centers
Pre-Insulated Wall Panel 50mm – 80mm Integrated Hydrophobic Rockwool (120kg/m³) + Metal Face Class A1 / A2 Zero Flame Spread 14.5 – 18.0 kg/m² Thermal U-value 0.28 W/(m²·K); dry-hang anchor 1,200 × 4,000 mm Energy-efficient envelopes, prefabricated exterior retrofits, industrial complexes
Architectural Solar Louver Heavy-Wall Extrusion Extruded Aluminum Alloy 6063-T5 / T6 Profiles Class A1 / A2 Structural Aluminum 8.5 – 16.0 kg/m² Aerodynamic foil; spans up to 4,500mm unassisted Up to 6,500 mm Length Solar heat-gain mitigation, dynamic facades, airport concourse daylight shading
Third-Party Testing & Verification

Certified to National (GB/T) & International Building Standards

Every architectural cladding and envelope system undergoes comprehensive batch audits and independent laboratory verifications across fire safety, dynamic wind loads, coating durability, and acoustic criteria.

local_fire_department Fire Reaction
GB 8624 & EN 13501-1
Class A1 / A2

NFTC tested. Non-combustible core, FIGRA ≤ 120 W/s, zero toxic smoke & flaming droplets for high-rise egress compliance.

shield_with_heart US Flame Code
ASTM E84 Class A
FSI = 0 · SDI < 15

Tunnel test verified. Zero flame spread index across monolithic and honeycomb assemblies for international terminal concourses.

air Wind & Water
GB/T 15227 & ASTM E330
Dynamic Wind Pressure 5.2 kPa

Full-scale dynamic chamber mock-up testing. Sustains 5,200 Pa cyclic gust loads and 600 Pa water tightness with zero penetration.

architecture National Veneer
GB/T 23443-2009
Tensile Yield ≥ 145–215 MPa

National standard for architectural aluminum veneers. Rigorous tensile, elongation, and peel strength (≥ 9 N/mm) compliance.

format_paint Coating Standard
AAMA 2605 / 70% PVDF
30-Year Coating Warranty

10-Year South Florida exposure test qualified. 3-coat 2-bake vertical line coating with color retention ΔE < 3.0 over 20–30 years.

waves Anti-Corrosion
ASTM B117 & ISO 9227
4,000h Salt Spray High Endurance

Accelerated marine environment verified. Corrosion creep < 0.5mm on AA5052-H32 alloy for coastal airports and port facilities.

hearing Acoustics
ASTM E90 & ISO 10140
Sound Transmission Rw 38–44 dB

Acoustic barrier testing for perforated ceilings, composite cassettes, and damped high-speed railway concourses.

verified_user Management
ISO 9001 / 14001 / 45001
Green Building Material Certified

Quality, environmental & occupational health three-system certified. Full CNAS batch traceability from raw coil to site crating.

description

Need Certified Laboratory Reports for Project Tender Submittals?

We supply complete formal test reports, including National Fireproof Building Materials (NFTC) test sheets, PVDF coating performance warranties, mill test certificates (EN 10204 3.1 MTC), and structural calculation sheets for commercial tenders.

Request Testing Dossier arrow_forward
Direct Facade Engineering Desk

Need Custom Dimensions, Perforation Patterns, or Engineered Mock-ups?

Submit your project schedule, wind-load parameters, or architectural elevations. Our technical facade team responds with preliminary structural sizing, BIM details (LOD 400), and formal CIF/FOB export pricing within 24 business hours.

schedule
24-Hour B2B Turnaround Guaranteed response for commercial procurement RFQs.
box
Global Sample Dispatch FedEx / DHL express sample boxes delivered worldwide.

Request Architectural Consultation & Tender Pricing

24H Response
* Required
* Required